Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note

Important

If the first instrument listed in the message has an invalid tag 107-SecurityDesc, the entire message is rejected. All instruments listed in the message must belong to the same Group Code. All instruments belonging to a different Group Code are rejected.

Repeating groups are designated within the message by the (→) symbol.

Tag

FIX Name

Req

Type

Description

117

QuoteID

Y*

String (10)

This is the identifier of the Quote Cancel message. It should be unique per trading session.

298

QuoteCancelType

Y

Int (1)

Always '1' (Cancel per Instrument)

295

NoQuoteEntries

Y*

Int (3)

Number of groups to be cancelled.

→55

Symbol

Y

String (6)

Group code of the contract. Must be the first tag in the repeating group.

→107

SecurityDesc

N

String (20)

Contract to be cancelled, i.e. ESZ5 C1115.

Y = FIX required Y* = CME Group required N = Not required