Contents
Table of Contents |
---|
Handoff Specifications
- 1 Gbps hand-off
- 10 Gbps hand-off
- Single Mode Fiber
- 10G-LR (10GBASE-LR)
...
Info |
---|
All connections at the 3rd party hosting facility are single-mode fiber. |
LNet Connectivity Procedures
Customer Requirements
LNet Customers must meet the following requirements:
...
- Please note that floor and suite location must be included on the Access Request Form or Schedule 2.
- Although CME Group facilitates the cross connect requests within the hosting facility, it is the customer’s responsibility to complete and/or approve any vendor agreements that may be applicable.
- Provide two routers or Layer 3 switches that will terminate each 1 or 10 Gbps, single-mode fiber cross-connect.
- The point-to-point IP address must be configured on the interface closest to CME Group device.
- CME Group recommends that the customer checks the Signal/Light levels at the time of turn up in order to attenuate levels to protect equipment.
- Verify connectivity requirements with the respective vendor.
- Avoid using media converters.
- The customer’s SFP or GBIC must be compatible with long wavelength/long haul SFPs.
- Please note there are specific prerequisites for firms interested in becoming a CME Group-approved 3rd party vendor that provides proximity services. Please contact Global Account Management (GAM) for more information.
Routing Requirements
Customer routers must be capable of using advanced TCP/IP Protocols including BGP and multicast, specifically PIM Sparse Mode.
- BGP routing must be used on the routers terminating CME Group connections.
- It is recommended that customers use a routing protocol between their routers to provide automatic failover.
- All IP packets destined for CME Group must be sourced from CME Group-assigned private address space.
- Multicast PIM Sparse Mode must be used.
Restrictions
The following restrictions apply to LNet connectivity:
- No site-to-site connectivity.
- No direct server connectivity into CME Globex.
- Terminating the circuit on a Layer 2 device is not allowed.
- CME Group will not accept traffic sourced from any customer’s public IP space.
- Only one Market Data Platform data feed per router is allowed.
- Customer hardware must be capable of supporting quote streams (e.g., PIM sparse mode).
- Customer equipment must be in CME approved space.