CME STP FIXML - Message Specifications for BrokerTec Trades

FIXML Message Elements and Attributes

Messages are comprised of elements, which may be non-repeating or repeating. Elements contain Attributes that define the trade characteristics.

  • Repeating Elements are indicated by "(repeating)" in the gray highlighted Element definition row.

  • Some Elements, such as Instrument (Instrmt), have a large number of attributes, and are therefore allocated their own page.

  • The first defined Element level on any specification page is considered the highest level for that page. Elements may have sub-elements on the same page, as indicated by an arrow () preceding the field name.

  • A sub-element one level down contains an arrow preceding it in the field name, for example: 

→ Sender ID

Elements two levels down will have two preceding arrows:

→→ Leg Underlying Product Code

  • The highest level on any page will not be preceded by an arrow, though it may still be a sub-element. For example, Instrument is a sub-element of Trade Capture Report Message, but because it is the highest level for that page, the Field Names will not be preceded by an arrow.

The order of attributes within elements is subject to change.

Required FIXML Element Attributes

The following attributes must be included on the FIXML element of each message sent to the CME STP, and will appear on all FIXML messages sent by the API.

Field

Description

Valid Value

Field

Description

Valid Value

FIX Version Number

Indicates the version of FIX being used (including Service Pack).

5.0 SP2

/FIXML/@v

Schema Release Date

Indicates the release date of the FIXML Schema.

20090815

/FIXML/@s

FIXML Extension Version

Indicates the FIX Extension version.

109

/FIXML/@xv

Custom Application Version

Indicates the Custom Application version.

CME.0001

/FIXML/@cv

Standard Header

All FIXML messages or Batch containers must include a Standard Header with the following four required fields. The following table indicates fields sent on messages from the user to the API. When responding to the user, the API will swap Hdr/@SID with Hdr/@TID, and Hdr/@SSub with Hdr/@TSub

Field

Description

Valid Value

Field

Description

Valid Value

Sender Comp ID

Indicates the sender of the message. Generally a firm level identifier.

Assigned by CME

Hdr/@SID

Target Comp ID

Indicates the recipient of the message. This value is always CME for inbound messages.

CME

Hdr/@TID

Sender Sub ID

Indicates the sender entity. This value must match the username sent via HTTP Basic authentication, and must be in all uppercase letters.

Assigned by CME

Hdr/@SSub

Target Sub ID

Indicates the recipient entity. This value is  always STP for inbound messages.

STP

Hdr/@TSub

Batch Container

CME STP returns trades (FIXML Trade Capture Report messages) to HTTP clients by encapsulating a single Standard Header followed by zero or more Trade Capture Report messages within the /FIXML/Batch element. The Trade Capture Report messages themselves will not contain Hdr elements themselves. CME STP may send an empty Batch, containing a Hdr but no TrdCaptRpt messages, either because a Query returned no results, or because no new activity occurred for a Subscription. However, in the case of an empty batch for a Subscription, the user must still extract the token and use it in subsequent requests.

A batch can return a maximum of 250 Trade Capture Report messages.  

Input Source

The Input Source field in the Trade Capture Report/RptSide block indicates the original system from which the trade originated. CME Clearing will treat this as a pass through field on cleared trade confirmations.

Example values include:

  • BRKR – Broker submission into FEC via UI or API, applicable to NY floor only.

  • CPC – CME ClearPort UI.

  • DLV - Delivery transfer. Represents the monthly delivering into a strip of individual daily positions and the transfer to establish the open position on the books of the firm or client.

  • GLBX, GBX – CME Globex.

  • FIRM – Clearing firm submission into FEC via UI or API.

  • HHT – CME handheld floor device, applicable to Chicago floor only.

  • OREC – Floor order routing e-Clerk, applicable to Chicago floor only.

Other values not listed above may be used for platform systems.