Quote Request - Business Level Reject
This message is submitted when an iLink Quote Request (tag 35-MsgType=R) message is rejected by CME Globex. In this instance, a Business Level Reject (tag 35-MsgType=j) message is sent with tag 380-BusinessRejectReason containing a value from the reject codes listed in the table.
Tag | FIX Name | Req | Type | Description |
---|---|---|---|---|
45 | RefSeqNum | N | Int (10) | Tag 34-MsgSeqNum of the message being rejected. |
372 | RefMsgType | Y | String (2) | Tag 35-MsgType of the message being rejected |
379 | BusinessRejectRefID | N | String (32) | Identifier of the rejected message, tag 131-QuoteReqID. |
380 | BusinessRejectReason | Y* | Int (2) | Code to identify the reason for rejection: |
58 | Text | Y* | String (80) | Additional information on the reject reason |
Y = FIX required Y* = CME Group required N = Not required
Example
If a Quote Request message is sent with an invalid tag 107-SecurityDesc, CME Globex will reject the message using a Business Level Reject (tag 35-MsgType=j) message with tag 380-BusinessRejectReason=2.