Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For more details to trade CME Group products via this connectivity method, contact your Globex Account Manager (GAM).

CME EConnect - NY5 connectivity provides access to:

...

Contents

Table of Contents

Handoff Specifications

  • 1 Gbps hand-off
  • 10 Gbps hand-off
  • Single Mode Fiber
  • 1G-LR (1GBASE-LH)
  • 10G-LR (10GBASE-LR)
  • 1310nm wavelength

...

Figure: EConnect NY5 Connectivity

CME Globex EConnect Connectivity Procedures

Upon successful validation of the cross connect and site acceptance by CME Group, the customer is responsible for the following procedures:

  • Activating the multicast stream
  • Configuring the customer application on the arbitration server
  • Configuring routers
  • Configuring the rendezvous point’s IP address
  • Configuring a fixed path between each router and corresponding CME data center
  • Validating that the listener server is receiving data from the correct source

Routing Requirements

Customer routers must be capable of using advanced TCP/IP Protocols including BGP and multicast, specifically PIM Sparse Mode.

  • BGP routing must be used on the routers terminating CME Group connections.
  • It is recommended that customers use a routing protocol between their routers to provide automatic failover.
  • All IP packets destined for CME Group must be sourced from CME Group-assigned private address space.
  • Multicast PIM Sparse Mode must be used.

Restrictions

The following restrictions apply to connectivity:

...