Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Contents

Table of Contents

Handoff Specifications

  • 1 Gbps hand-off
  • 10 Gbps hand-off
  • Single Mode Fiber
  • 10G-LR (10GBASE-LR)

...

Info
All connections at the 3rd party hosting facility are single-mode fiber.

LNet Connectivity Procedures

Customer Requirements

LNet Customers must meet the following requirements:

...

  • Please note that floor and suite location must be included on the Access Request Form or Schedule 2.
  • Although CME Group facilitates the cross connect requests within the hosting facility, it is the customer’s responsibility to complete and/or approve any vendor agreements that may be applicable.
  • Provide two routers or Layer 3 switches that will terminate each 1 or 10 Gbps, single-mode fiber cross-connect.
  • The point-to-point IP address must be configured on the interface closest to CME Group device.
  • CME Group recommends that the customer checks the Signal/Light levels at the time of turn up in order to attenuate levels to protect equipment.
  • Verify connectivity requirements with the respective vendor.
  • Avoid using media converters.
  • The customer’s SFP or GBIC must be compatible with long wavelength/long haul SFPs.
  • Please note there are specific prerequisites for firms interested in becoming a CME Group-approved 3rd party vendor that provides proximity services. Please contact your contact Global Account ManagerManagement (GAM) for more information.

Routing Requirements

Customer routers must be capable of using advanced TCP/IP Protocols including BGP and multicast, specifically PIM Sparse Mode.

  • BGP routing must be used on the routers terminating CME Group connections.
  • It is recommended that customers use a routing protocol between their routers to provide automatic failover.
  • All IP packets destined for CME Group must be sourced from CME Group-assigned private address space.
  • Multicast PIM Sparse Mode must be used.

Restrictions

The following restrictions apply to LNet connectivity:

  • No site-to-site connectivity.
  • No direct server connectivity into CME Globex.
  • Terminating the circuit on a Layer 2 device is not allowed.
  • CME Group will not accept traffic sourced from any customer’s public IP space.
  • Only one Market Data Platform data feed per router is allowed.
  • Customer hardware must be capable of supporting quote streams (e.g., PIM sparse mode).
  • Customer equipment must be in CME approved space.