...
View this video for a brief overview of the Certification environments.
System Requirements
AutoCert+ supports connections that meet the requirements listed on the Supported Browsers page.
...
Info |
---|
AutoCert+ functional/certification testing allows a maximum of 10 Transactions Per Second (TPS). A maximum of 70 TPS is allowed for performance testing. In order to enable performance testing (greater than 10 TPS), you must contact Global Account Management. |
Log into AutoCert+ at the following link: https://autocert.cmegroup.com/.
Customer Support
For additional information regarding client system certification, contact the following CME Group departments:
Certification Support for Electronic Trading (CSET)
Prerequisites for Certification
To connect and test in the testing environments complete the following:
- Request and configure your new network connection by contacting Global Account Management.
- You are invited to discuss other network options with your Global Account Manager.
This network connection allows you to perform functional testing on both environments and also to access AutoCert+.
- Create new iLink IDs for each environment.
- You can choose the firm IDs that you are using in production to perform front-end to back-end system testing.
- Third-party system providers can provide and set up temporary IDs to perform functional testing.
- The iLink IDs used for connecting to the testing environments are the same as those used for certifying on AutoCert+.
- The Session IDs indicate which environment you are connected to. If the ID is alpha-numeric-numeric (i.e. C28), you are connected to New Release environment. If the ID is numeric-alpha-numeric (i.e. 7E8), you are connected to Certification environment.
- You can choose the firm IDs that you are using in production to perform front-end to back-end system testing.
- Download the network configuration file for the applicable environment.
CME Request Center NR/Cert
CME Request Center NR/CERT is available to all CME Group Logins registered in AutoCert+. With CME Request Center NR/CERT, you can:
...
- Login to CME Request Center NR/CERT
- CME Request Center NR/CERT User Help System
Network Connectivity
The client system connects to AutoCert+ and processes data sent by CME Group as shown in this diagram. For example, a client system certifying on MDP functionality must join the MDP feed and process market data according to the test requirements. Please refer to the Network Connectivity topic for comprehensive information related to network connectivity solutions.
Gliffy | ||||||
---|---|---|---|---|---|---|
|
Environments
These environments are in separate data centers and have distinct connectivity. EBS clients should select the testing environment(s) that support the trading platforms, modes, and services they need.
...
Gliffy | ||||
---|---|---|---|---|
|
iLink Certification
General iLink Tag Requirements
Please note the following before certifying your application:
...
For more information regarding the certification tests, refer to the AutoCert+ User Help System associated with each test.
SenderCompID Naming Convention
To successfully run and track tests, a System Profile needs to be associated with a SenderCompID. SenderCompIDs are created and assigned to a company. A tester may choose from among the SenderCompIDs available for their company. This SenderCompID then belongs to the tester as long as the tester remains logged into the AutoCertPlus web application or until the tester chooses to un-assign the SenderCompID.
...
- Certification Environment: SenderCompID = 7E8640N
- New Release Environment: SenderCompID = C28123N
Separate Sender CompID Per Environment
The Session ID, Firm ID and Password are assigned and can be obtained by contacting your Global Account Manager. You must obtain a session ID before being able to run any of the certification tests for AutoCert+. If you have more than one application to certify, you can obtain more than one ID.
Info |
---|
You must obtain a separate SenderCompID for the New Release environment and the Certification environment. You cannot use one SenderCompID for both environments. |
Market Data Platform Certification
Each environment has its own set of Market Data Platform multicast channels. Channel information for both environments is available on the CME Group FTP/SFTP site as described in CME Market Data Platform.
The Market Data Platform architecture is explained in terms of a market data group. A market data group is a set of UDP channels used to produce market data messages for a set of instruments and/or a set of instrument groups. Market data is organized by Market Data Group, which is a configuration of MDP channels providing all market data required to support markets for a given product or set of products.
- Each channel is assigned a “Dummy Contract”
- Instrument Definition Channels
- Incremental Feed “A” Channels
- Incremental Feed “B” Channels
- Market Recovery Channels
Channel Definitions
To obtain channel definitions for AutoCert +, visit the FTP/SFTP site and navigate to the current XML configuration file for MDP 3.0 or streamlined SBE:
...
Info |
---|
For the AutoCert+ environment, the Instrument Definition and Market Recovery feeds will support a lower mps (message per second) than the other testing and production environments. |
EBS Testing
EBS Workstation Testing
EBS Workstation is deployed in the CME Globex New Release (DC3) environment and supports access to:
- EBS Market and eFix Matching Service
- EBS Direct
EBS Market Testing
EBS Market Central Limit Order Book and eFix Matching Service on CME Globex are available for client testing and functional certification in the CME Globex New Release environment. Clients must submit the Environment Access Request and Change Form for EBS on CME Globex to access the CME Globex New Release environment.
Environment | Location | Trading Mode/Platform | Service | Connectivity Options |
---|---|---|---|---|
CME Globex New Release | DC3, Aurora, IL |
| iLink 3 | |
CME Globex New Release | DC3, Aurora, IL |
| Drop Copy | Cert VPN Cert Data Center |
CME Globex New Release | DC3, Aurora, IL |
| MDP 3.0 services | Cert VPN Cert Data Center |
CME Globex New Release | DC3, Aurora, IL |
| EBS Spectrum Market Data | Cert VPN Cert Data Center |
CME Globex New Release | DC3, Aurora, IL |
| EBS Workstation GUI | Internet |
Cloud Based | AWS |
| Reference Data API | Internet |
EBS Customer Lab | NY2, Secaucus, New Jersey |
| CPT TOF and FIX | VPN Stunnel |
EBS Direct Testing
Environment | Location | Trading Mode/Platform | Service | Connectivity Options |
---|---|---|---|---|
CME Globex New Release | DC3, Aurora, IL |
| EBS Workstation GUI | Internet |
EBS Customer Lab | NY2, Secaucus, New Jersey |
| CPT TOF and FIX | VPN Stunnel |
EBS Customer Lab | NY2, Secaucus, New Jersey | EBS Direct 2.0 | Generic Liquidity Provider API | VPN Stunnel |
EBS Customer lab | NY2, Secaucus, New Jersey | EBS Direct 2.0 | Bespoke Liquidity Provider API | VPN Stunnel |
EBS Customer Lab | NY2, Secaucus, New Jersey | EBS Direct 2.0 | Liquidity Consumer API (FIX 4.4) | VPN Stunnel |
Environment Schedules
CME Globex services in Certification and New Release are available from: 8 pm CT Sunday to 4 pm CT Friday, except for a weekly maintenance window:
...
Maintenance windows are a specified period of time during which an environment is unavailable in order to allow CME Group staff to launch and test new releases, and perform maintenance operations.
AutoCert+ User Help Systems
For more information and instructions regarding specific certification tests, refer to the AutoCert+ User Help System related to each test.
Production Environment
See details about the CME Globex Production environment and connectivity options for all markets and services.
...