MDP 3.0 - Terminate

MDP 3.0 - Terminate

This message maps to the Terminate template in the TCP Session Management SBE Schema.  Both client systems and the exchange use this message.

 

Tag

FIX Name

Type

Semantic Type

Valid Values

Description

39011

Reason

String48

String

 

Reject reason details

39001

UUID

uInt64

int

 

Matches Negotiate.UUID used to establish the connection

39002

RequestTimestamp

uInt64

UTCTimestamp

 

Time of request; recommended to use timestamp as number of nanoseconds since Unix epoch (Jan 1, 1970)

39012

ErrorCodes

ErrorCodes

int

0=Unknown Security

1=Unknown or Invalid Message

2=Unsupported Scope

3=Other

Error code for reject reason

 

 

 