Session Level - Reject
CME Globex issues the Session Level Reject (tag 35-MsgType=3) message when the inbound (client sysÂtem to CME Globex) message fails to pass a CME Globex session-level validation check. These messages have invalid basic data (e.g., CheckSum and BodyLength), but successfully passed de-encryption validations. The reason a message is rejected is described in tag 58-Text field. Â
Reasons that a Session Level Reject (tag 35-MsgType=3) message is sent include:
Required tag missing
Undefined tag included
Tag specified without a value
Value is incorrect (out of range or invalid) for this tag
Incorrect data format for value
CompID problem
SendingTime accuracy problem
CME Globex Credit Controls credit limit violation
See Session Layer Validation Conditions for more information.
The following diagram illustrates an unsuccessful message transmission and Session Level Reject (tag 35-MsgType=3) scenario.
In this diagram the client system sent a Logon message without tag 35-MsgType. As a result, CME Globex issued a Session Level Reject (tag 35-MsgType=3) with a descriptive reason in tag 58-Text.
If a client system submits a message that cannot be parsed or fails a data integrity check, iLink 2 will not send a response message. In such a scenario, when the next valid message is processed, iLink 2 will detect a sequence gap and generate a Resend Request (tag 35-MsgType=2) message. If the client system resends the corrected message and it is valid, normal processing will continue.
Warning
If the previously invalid message remains in error and the client system continues to send the message without making the required corrections, the Resend Request (tag 35-MsgType=2) message process will loop indefinitely. Clients must detect this condition and perform the corrective processing to avoid it.
How was your Client Systems Wiki Experience? Submit Feedback
Copyright © 2024 CME Group Inc. All rights reserved.